Greške na GRUNDIG GSC 200

GRUNDIG GSC 200
477
AFC KRUG OSCILIRA TITRAJUĆI SLIKOM OD DOBRE DO SNIJEŽNE SLIKE (1 DO 10 Hz)
LOŠ REFERENTNI NAPON NA PLOČICI MEĐUFREKVENCIJE (9,1V) ZBOG LOŠE MASE ZENER DIODE. REFERENTNI NAPON SE NE SMIJE NI U KOJOJ SITUACIJI MIJENJATI.

GRUNDIG GSC 200
1520
NE RADI
IZGORIO OSIGURAČ SI2602 (630mA) U NAPAJANJU 15V (+F), ODLOTAN R607 JER JE PROBIO TANTAL C1207 U NAPAJANJU IC PRIJEMNIKA

GRUNDIG GSC 200
1107
NEMA SKALE PROGRAMA KOD TRAŽENJA KANALA
RAZLOTANO PODNOŽJE KONEKTORA SL-BAUSTEINA (CPU KARTICA)

GRUNDIG GSC 200
1521
NEMA SLIKE, A KAD SE JAVI POJAVI SE SAMO VERTIKALNA TRAKA SLIKE SA LIJEVE STRANE
PREKID OTPORNIKA R926 (100K) NA RGB BAUSTEINU. GREŠKA SE MOŽE POTVRDITI MJERENJEM NAPONA NA PINU 3 TDA2800. NAPON MORA BITI OKO 12 V SA VERTIKALNIM IMPULSIMA ZATAMNJENJA.

GRUNDIG GSC 200
612
NEMA TONA
RAZLOTAN KONEKTOR OD ABSTIMMUNG BAUSTEINA, LOŠI ELEKTROLITI OKO SN29799 (C373,C372), ISHLAPIO 10uF U MF-U C2331

GRUNDIG GSC 200
1534
NESTABILNA VERTIKALA
LOŠ TRIMER ZA VERTIKALNU AMPLITUDU (BA) R442

GRUNDIG GSC 200
1106
POVREMENO NESTAJE BOJA
RAZDEŠENA PLOČICA RGB BAUSTEIN, PREKID TRIMERA

GRUNDIG GSC 200
1652
PREKLOPLJENA SLIKA PO VERTIKALI ODOZDO
LOŠ BOOTSTRAP ELEKTROLIT 100uF/25V NA PLOČICI VERTIKALNOG IZLAZA

GRUNDIG GSC 200
1533
SLIKA SE GASI U TOČKU
TRIMER SG (R545) U PREKIDU - PREVELIK NAPON NA UG2. PODEŠEN FOKUS

GRUNDIG GSC 200
1651
VERTIKALNA SINKRONIZACIJA NE RADI
LOŠ TRIMER (75K) ZA PODEŠAVANJE FREKVENCIJE VERTIKALNOG OSCILATORA (TRIMER BILD)